General:

This new energy saving Passive Infrared wall switch utilizes an integrated circuit manufactured with the latest surface mount technology, has excellent detection sensitivity and a rapid response time. Its design incorporates automatism, convenience, safety, energy-saving and practical functions. The wide detection range senses an up, down, left and right field of motion. It works by seeing human body heat in motion via infrared rays. It is designed to replace an existing wall switch for interior lighting. It can start the controlled output load (light) immediately when a person crosses the detection field and it will not switch on unless the room is dark or dimly lit. The unit incorporates a simple three wire installation, a status indicator LED light and built-in photocell.

FEATURES

  This switch controls: incandescent bulbs, compact florescent bulbs (CFL) and florescent fixtures with Electronic Ballast.

  Relay motion sensor occupancy switch. No flickering with CFL and Florescent Bulbs with Electronic Ballast.

  Power frequency: 50~60Hz

  Control light: <3 LUX ~ 2000 Lux (Adjustable)

  Time-Delay: Minimum:8sec±3sec to a Maximum:7min±2min
  Power source: 100V/AC~130V/AC <=> 220V/AC~240V/AC

  1200W(220V/AC~240V/AC) - 800W(100V/AC~130V/AC)

   Power consumption:0.45W(static 0.1W)

  Detection range: 180°
  Detection distance: 12 meters maximum at less than 24°C

  Working temperature:-20 to 40°C

  Working humidity: Less than 93% Relative Humidity

  Suggested Installation height: 0.5 meter to 3.5 meters

  Detection motion speed: 0.6 to 1.5 meters per second
  THIS IS NOT A SINGLE POLE SWITCH. IT NEEDS HOT AND NEUTRAL WIRES WELL IDENTIFIED IN ORDER TO WORK. Please see the installation diagram below.

 

Function

Correct moving orientation-------------- incorrect moving orientation

Installation (see the following diagram)

   

Connection-wire diagram

Test

Notes:

TROUBLE SHOOTING


1. In the case where the light(s) connected to the sensor won’t switch on: .
a. If the LED light is flashing check the load (light) or the switch connections, if the LED light is not flashing at all please check the power, the main fuse or circuit breaker.
b. Please check if the room lighting is low level and within the 10 LUX threshold.

2. In the case that the sensitivity is poor:
a. Please check if the front of the detection window is somehow blocked.
b. Please check the ambient temperature.
c. Please check if the movement source is within range of the sensor.
d. Please check the installation height.
e. Please check if the direction of movement is perpendicular to the sensor switch.

3. In the case where the output load will not shut off:
a. Please check if there is anything emitting heat and also moving air in the detection field.
b. Pleased check the time delay relative to the last detected motion within range.
c. Please ensure that the power is within the operating range.
e. Mirrors can reflect motion in the sensor view, check to see if the sensor is facing a mirror and if the mirror is facing some moving warm object.